#470 - 10/28/08 09:06 PM Thermostat for Vistaflame VF100 FS
Sigma40



Registered: 10/28/08
Posts: 1
We are in the process of taking the VistaflameVF100 FS out of our shop and installing it in our dinning room/familyroom. Is it possible to put a thermostat on this stove.

I put the stove in my shop in 04 and used 6 bags of pellets in 4 years. LP Gas has gone too high so i thought that this stove would work better in the house.


Edited by Sigma40 (10/28/08 09:07 PM)

Top
#475 - 11/13/08 03:07 AM Re: Thermostat for Vistaflame VF100 FS [Re: Sigma40]
Andy Silven Moderator
Stove Expert
*****

Registered: 09/19/04
Posts: 151
Loc: Oregon
The age of the stove and the kind control panel that came with the stove will determine weather or not the stove will work as a on / off or high / low operation if the stove is using a solid state controls it is high / low and if it is using a PC board then it will operate as a on / off remember that using a thermostat will reduce the life of your igniter by 35% and most likely increase your ash build up in the firebox and chimney which means more cleaning...efficiency on stoves using a thermostat is reduced during start up. The connections for the UL thermostat wire are located on the back of the control board and be sure to use a 24v (low voltage) thermostat and do not use more then 20' of wire